08-09

2021


Electrical, thermal, and measuring instruments and protective devices for compressed air stations

The power load level of the compressed air station should be determined according to the importance of compressed air usage by the user, in accordance with the current national "Power Supply and Distribution System Design Specification" (GB50052) load classification regulations. Except for those where interruption of compressed air would cause significant losses, it is recommended to use a Class 3 load.

08-09

2021


Water supply and drainage for compressed air station

The production water for the compressed air station should use a single water supply, as interruption of compressed air supply would cause significant losses. The cooling water for the compressed air station should be recycled. A single-pump cooling system is recommended for the circulating water system.

08-09

2021


Civil works for compressed air station

The height of the lower chord or bottom of the beam in the compressed air station machine room should meet the requirements of equipment disassembly, lifting, and ventilation. The net height should not be less than 4m. In hot summer and cold winter and hot summer and warm winter areas, if the machine room span is greater than 9m, it is advisable to install skylights.

08-09

2021


Compressed air piping of the compressed air station

Compressed air pipelines should meet user requirements for compressed air flow, pressure, and quality. The needs of near-term development should also be considered. The layout of compressed air pipelines in the plant (mine) area should be determined based on comprehensive factors such as meteorological, hydrological, geological, and topographical conditions, as well as ease of construction, operation, and maintenance.

08-09

2021


Composition and equipment layout of the compressed air station

In addition to the machine room, a utility room should be set up for the compressed air station. Its composition and area should be determined based on comprehensive factors such as the scale of the compressed air station, the type of air compressor, the maintenance system, operation management, and internal corporate collaboration conditions.

08-09

2021


Applications in low-temperature compressed air generation

In some cases, users require low-temperature compressed air, such as for simulating high-altitude air environments, which requires -55℃ compressed air. -55℃ means that the dew point of the compressed air must be below -55℃; otherwise, the compressed air will freeze and cause ice blockage during the freezing process. Therefore, the key to this project is to lower and maintain the dew point of the compressed air below -55℃. To meet the above requirements, a modified combined dryer is used, placing the adsorption dryer in front of the refrigeration equipment. Through adsorption drying, the compressed air is dried to a pressure dew point of -60℃, ensuring that the compressed air entering the refrigeration equipment

06-25

2021


We are committed to introducing Enko products to every user and providing the most considerate service to every Enko user.

As a core member of INCO, INCO Shengshi (Beijing) Science and Technology Development Co., Ltd. is dedicated to introducing INCO products to every user and providing the most considerate service. The world pays attention to China, and we pay attention to the world. Whether now or in the future, INCO will provide clean and dry power for your success.

< 123 >
Ourinco

Get Quote


We will wholeheartedly provide you with high-quality products and services.

Submit