Installation of thermal measurement instruments at the screw air compressor station

Release time:

2021-08-09

Author:

Source:


Abstract

Serial Number

Measurement Point Name

Installation

I. Temperature

1

Exhaust gas temperature of each section

Should

2

Inlet air temperature of each section

Should

3

Oil cooler outlet oil temperature

Should

4

Bearing temperature

Should

5

Cooling water inlet temperature of the main water pipe

Should

6

Unit outlet water temperature

Should

7

Aftercooler outlet water temperature

Should

II. Pressure

1

Air compressor station supply air header pressure

Should

2

Air compressor exhaust pressure

Should

3

Air compressor unit cooling water inlet (after valve) pressure

Should

4

Lubricating oil pressure (at lubrication point)

Should

III. Flow Rate

1

Air compressor unit outlet flow rate

Should

2

Air compressor station supply air header flow rate

Should

Note: The installation of measuring instruments for the air drying and purification device is the same as Table A.

Recommended Reading


Applications of low-pressure, high-volume compressed air dryers


The same warehouse transports different raw materials between different countries. In this case, warehouse cleaning becomes the most important link in ensuring that goods are not contaminated.

2021-08-09

Comparison of various suction machine performances


Different adsorption regeneration methods will have differences in drying depth, air consumption, working cycle, equipment structure, etc., each with its own characteristics.

2021-08-09

Process system


The model, quantity of air compressors, and air supply systems with different air quality and pressure should be determined based on air supply requirements, compressed air load, and technical and economic comparisons. Within the compressed air station, the number of reciprocating or screw air compressors should be 3-6 units. For air supply systems of the same quality and pressure, the number of air compressor models should not exceed two. The number of centrifugal air compressors should be 2-5 units, and the same model should be used.

2021-08-09

Ourinco

Get Quote


We will wholeheartedly provide you with high-quality products and services.

Submit