Water supply and drainage for compressed air stations


In addition to the significant losses that would result from interrupting compressed air supply, the production water supply for the compressed air station should use a single water supply route.

The cooling water for the compressed air station should be recycled. A single-pump cooling system is recommended for the recirculating water system.

The cooling water pressure (gauge pressure) at the inlet of the air compressor should meet the following requirements:

1. For reciprocating air compressors, the pressure should not exceed 0.4 MPa and should not be less than 0.1 MPa;

Note: Applicable to reciprocating air compressors manufactured in accordance with "Technical Conditions for General-Purpose Stationary Reciprocating Air Compressors" (GB/T13279-91).

2. For screw air compressors, the pressure should not exceed 0.4 MPa and should not be less than 0.15 MPa;

3. For centrifugal air compressors, the pressure should not exceed 0.52 MPa and should not be less than 0.15 MPa.

The water quality standards for the cooling water of the air compressor and its cooler should comply with the provisions of the current national standard "Design Specifications for Industrial Recirculating Cooling Water Treatment" (GB50050). When softened water is available within the enterprise and the system is economical and reasonable, the circulating water in the system can use softened water.

When using a direct flow system to supply cooling water to the air compressor and its cooler, the drainage temperature should be controlled according to the carbonate hardness of the cooling water and should not exceed the limits specified in Table 7.0.5. If the value exceeds the limit specified in Table 7.0.5, the cooling water should be softened.

Relationship between Carbonate Hardness and Drainage Temperature

Carbonate Hardness ( In CaO terms mg/L

Drainage Temperature

140

45

168

40

196

35

280

30

A water flow observation device or flow controller must be installed on the drain pipe of the air compressor.

The water supply and drainage pipelines of the compressed air station should be equipped with facilities for draining the stored water.

Relevant Cases


Keshida Auto Electric, Changchun

RD0030 2 units

Hulunbuir Water Plant

RD0080 2 units

Dongfang Jingyuan Microelectronics

RD0020 and ADL002, 2 units each

Beijing Aqi Xiamier Industrial Electronics

RD0020 2 units

Beijing Nanrui Zhicixin Microelectronics

RD0010 One unit

Beijing Puna Microelectronics

ADH003 one unit

China Electronics Smart Card

One unit each of RD0200 and ADH020

BOE

One unit each of RD0120 and ADH020

Kuodan Lingyun Automobile

ADL010 One unit

Beijing Shun Heng Da Auto Parts

RD0120 One unit

Beijing Guanghua Rongchang Auto Parts

RD0010 3 units

Beijing Xinhan Auto Parts

RD0120 One unit

Xin Cheng Auto, Baoding

RD0200 One unit

Suizhou Aolong Automobile

One unit each of RD0100 and RD0200

Sichuan Toyota Automobile

ADL040 One unit

Huadu Foods

One unit each of RD0030 and ADH005

Shanghaojia

One unit each of RD0020 and ADL002 (stainless steel)

Beijing Binbao Food

ADL012 one unit

Beijing Manhattan Food

RD0250 1 unit

Beijing Hollyland

One unit each of RD0020, RD0060, RD0150, and ADH006 (stainless steel)

Product Consultation


Dedicated to provide you with quality products and professional services, please keep the phone open, We will contact you as soon as possible, thank you for your support!

Ourinco

Get Quote


We will wholeheartedly provide you with high-quality products and services.

Submit