  • 冷冻式干燥机配件--机械式自动排水器-x.jpg
  • 冷冻式干燥机配件--机械式自动排水器-xx.jpg

Refrigerated dryer accessories, mechanical automatic drain


Float-type automatic drainers differ in structure from traditional mechanical automatic drainers and are continuous drip drainers.

Product Information


Product Introduction

Performance Characteristics:

The float-type automatic drain differs in structure from traditional mechanical automatic drains; it is a continuous drip-drain type. The housing is made of die-cast aluminum alloy with a powder-coated surface for corrosion resistance inside and out. It contains a stainless steel float drainage system. This product is reliable, quiet, requires no electricity, has no compressed air loss, and is not easily clogged. It is the best choice for compressed air drain valves.

Working Principle:

This automatic drain uses a die-cast aluminum housing and contains a float drainage system. When the drainage buoyancy is less than the weight of the drainage float and the pressure applied by the compressed air, the drain port is closed; when the buoyancy rises, the drainage float rises, and the drain port opens; when the condensate decreases, the drain port closes again, and this cycle repeats.

Application Range:

Widely used for gas-liquid discharge in low-flow compressed air filters. It is generally recommended for use with precision filters with a processing capacity of 10 Nm³/min or less. For compressed air filters with higher processing capacities and more impurities, it is recommended to use the electronic drain valve MIC-A or MIC-B. The discharged oil-water mixture should be treated using our FYB series box-type waste oil collector or FYP series tank-type waste oil collector before being discharged into the environment.

Condensate Inlet/Outlet

1/2"

Maximum Operating Pressure

20Bar

Maximum Operating Temperature

100oC

Maximum Discharge Capacity

500 liters/hour

Installation Requirements:

★The actual operating pressure and temperature must not exceed those indicated on the label.

★Before installing the JAD20 drain, first remove dirt, copper shavings, rust, etc., from the compressed air system. It is recommended to drain the system under full pressure for 1 minute before installation.

★During installation, this automatic drain must be installed below the equipment's drainage device; otherwise, the condensate will fill up, affecting the drainage effect.

★The JAD20 drain port can be used as a "free outflow port" or a drain pipe can be installed.

Maintenance and Care:

Please inspect the drain valve regularly.

Operating Method: Open the manual drain valve to allow the water in the drain to flow out completely until compressed air enters the inner cylinder of the float for a few minutes, then close the valve. If more than 0.5 liters of water is drained, it indicates that the automatic drain is clogged and must be thoroughly cleaned.

The automatic drain should be disassembled and its internal components cleaned annually. When cleaning, soapy water or detergent can be used. Do not use organic solvents to avoid damaging rubber components.

Keywords:

Mechanical automatic drain

freeze dryer accessories

Ourinco

Get Quote


We will wholeheartedly provide you with high-quality products and services.

Submit