Refrigerated dryer accessories pressure switch


Working principle: The diaphragm is driven by the compressor exhaust pressure to generate displacement, which pushes the controller contacts to close and open. When the exhaust pressure is low, the diaphragm moves, causing the circuit to open and the condensing fan to stop working, causing the condensing pressure to rise; when the exhaust pressure rises to a certain value, the circuit is closed and the fan starts. Although the condensing pressure fluctuates to a certain extent under this control method, it can basically ensure that the condensing pressure will not be too low when the ambient temperature is low.

Product Information


 
Advanced energy-saving control technology
 
 
Select high-quality, high-efficiency carbon molecular sieves to ensure nitrogen purity
 
 
The equipment can self-adjust to meet the needs of nitrogen with different pressures and purities
 
  •  
    Use a highly reliable zirconia sensor to ensure accurate measurement of nitrogen purity
     
  •  
    Equipment self-protection configuration, real-time monitoring of intake quality, if the intake quality does not meet the standard, the inhaled compressed air will be discharged
     
  •  
    Real-time monitoring and control of nitrogen flow, purity and pressure
     

Applicable environment

  • Tools and instruments
  • Control system
  • Spraying tools
  • Injection successful
  • Car shop
  • Tire pressure

Product introduction

Pressure switches (also called pressure controllers) are used in refrigeration and air conditioning systems to avoid excessively low suction pressure and excessively high discharge pressure. Controllers can be used to start and stop refrigeration compressors and fans with air-cooled condensers.

Working principle:

The discharge pressure of the compressor drives the diaphragm to generate displacement, pushing the controller contacts to close and open. When the discharge pressure is low, the diaphragm moves, causing the circuit to open, the condensing fan stops working, and the condensing pressure rises; when the discharge pressure rises to a certain value, the circuit is connected, and the fan starts. Although the condensing pressure fluctuates under this control method, it can basically ensure that the condensing pressure is not too low when the ambient temperature is low.

Large-scale refrigeration dryers use high and low pressure switches, namely double pressure controllers, which have two versions: both the left and right sides can be adjusted for high pressure, or the left side for low pressure adjustment and the right side for high pressure adjustment (LP signal version or LP+HP signal version). Enclosure protection level: IP30 or IP44

Small refrigeration dryers use high-pressure pressure controllers.

High and low pressure switch

High pressure switch

Pressure switches (also called pressure controllers) can be used to start and stop refrigeration compressors and fans with air-cooled condensers.